The reason and solution of a messy knife in the processing center

release time:2023-02-06


1. This situation may be caused by problems with the processing center of the processing center. The operator will use the reset button to change the calculation method, or just press the emergency stop button.

2. At the same time, the typical processing center PLC program (PLC programming is a digital operation electronic system designed for industrial environment applications) to update the tool table after changing. Your program should be like this, but after your tools have problems, you just need to put the knife down. After repair, I think there is no problem on the original knife rack, and there will be a chaotic knife.

The reason and solution of a messy knife in the processing center(图1)

3. Communicate with the manufacturer you purchased. If the manufacturer has after -sales service or after -sales maintenance, you can ask their technicians to check the safety. In addition, after the knife is disorderly, remember not to operate the operation panel keyboard of the machining center. If you don't understand PLC, try using external forces to help the knife set to complete. Pay attention to safety during the operation. Try to make the processing center tool library itself complete the entire M6 cycle, so that it will not be confused.

4. When changing the knife normally, due to the insufficient pressure of the knife, the sword changing process is stuck. After the manual blade is reset, the knife is a mess.

5. When the machine changes the knife of the machining center, the operator presses the RESET reset or the urgent stop button. The accident caused by the knife to change the knife may cause the knife to mess with the knife.

6. The phenomenon of turbulent knife caused by damage to the mechanical structure of the machine or the loss of CNC system parameters.

Methods of the processing center knife and knife:

1). See if the counter switch is loose and whether there is a knife. If there is, it is easy to mess with the knife.

2). Check the signal of the loose knife, the upper and lower signals of the knife cover, and the main axis positioning signal.

3). If there is a high and low -grade conversion function, check high and low -end signals. When calling the alarm, check which signal in the T picture has not arrived or flashed. The other may not be strictly compilation of T -chart.

4). If this processing center is used by others, do they adjust the positive and reverse motor of the blade in private. If this is the case, the knife library can only rotate in one direction, so you can't find the knife nearby, and the knife library will be chaotic.